Keysight Models 6811C, 6812C, and 6813C Programming Guide 135
LIST:COUNt
This command sets the number of times that the list is executed before it is
completed. The command accepts parameters in the range 1 through 9.9E37, but
any number greater than 2E9 is interpreted as infinity. Use INFinity to execute a
list indefinitely.
:SHAPe <shape>{, <shape>} Sets the waveform shape list
:POINts? Returns the number of shape list points
:STEP <step> Specifies how the list responds to triggers (ONCE | AUTO)
:TTLTrg <bool>{, <bool>} Defines the output marker list
:POINts? Returns the number of output marker list points
:VOLTage
[:LEVel] <n>{, <n>} Sets the voltage list
:POINts? Returns the number of voltage level points
:SLEW <n>{, <n>} Sets the voltage slew list
:POINts? Returns the number of voltage slew points
:OFFSet <n>{, <n>} Sets the voltage offset list
:POINts? Returns the number of voltage offset points
:SLEW <n>{, <n>} Sets the offset voltage slew list
:POINts? Returns the number of offset voltage slew points
[SOURce:]
LIST
Command syntax [SOURce:]LIST:COUNt <NRf+> | INFinity
Parameters 1 to 9.9E37 | MINimum | MAXimum | INFinity
*RST value 1
Examples
LIST:COUN 3 LIST:COUN INF
Query syntax [SOURce:]LIST:COUNt?
Returned parameters <NR3>
Related commands LIST:CURR LIST:FREQ LIST:TTLT LIST:VOLT