3 Language Dictionary
154 Keysight Models 6811C, 6812C, and 6813C Programming Guide
Source Subsystem (Voltage) Commands
This subsystem programs the output voltage of the ac source.
Subsystem syntax
[SOURce:]
VOLTage
[:LEVel]
[:IMMediate]
[:AMPLitude] <n> Sets the AC rms voltage amplitude of the ac source
:TRIGgered
[:AMPLitude] <n> Sets the transient voltage amplitude of the ac source
:AUXiliary
[:LEVel]
[:IMMediate]
[:AMPLitude] <n> Sets the AC rms voltage amplitude of the auxiliary
output
:MODE <mode> Sets the voltage mode (FIX | STEP | PULS | LIST)
:OFFSet
[:IMMediate] <n> Sets the DC offset voltage
:MODE <mode> Sets the offset mode (FIX | STEP | PULS | LIST)
:TRIGgered <n> Sets the transient DC offset voltage
:SLEW
[:IMMediate] <n> | INFinity Sets the voltage slew rate
:MODE <mode> Sets voltage slew mode (FIX | STEP | PULS | LIST)
:TRIGgered <n> | INFinity Sets the transient voltage slew rate
:PROTection
[:LEVel] <n> Sets the overvoltage protection threshold
:STATe <bool> Sets the overvoltage protection state
:SENSe | :ALC
:DETector <type> Sets the sense detector (RTIM | RMS)
:SOURce <source> Sets voltage sense source (INT | EXT)
:SLEW
[:IMMediate] <n> | INFinity Sets the voltage slew rate
:MODE <mode> Sets voltage slew mode (FIX | STEP | PULS | LIST)
:TRIGgered <n> | INFinity Sets the transient voltage slew rate