EasyManua.ls Logo

Keysight Technologies 6811C

Keysight Technologies 6811C
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Language Dictionary
154 Keysight Models 6811C, 6812C, and 6813C Programming Guide
Source Subsystem (Voltage) Commands
This subsystem programs the output voltage of the ac source.
Subsystem syntax
[SOURce:]
VOLTage
[:LEVel]
[:IMMediate]
[:AMPLitude] <n> Sets the AC rms voltage amplitude of the ac source
:TRIGgered
[:AMPLitude] <n> Sets the transient voltage amplitude of the ac source
:AUXiliary
[:LEVel]
[:IMMediate]
[:AMPLitude] <n> Sets the AC rms voltage amplitude of the auxiliary
output
:MODE <mode> Sets the voltage mode (FIX | STEP | PULS | LIST)
:OFFSet
[:IMMediate] <n> Sets the DC offset voltage
:MODE <mode> Sets the offset mode (FIX | STEP | PULS | LIST)
:TRIGgered <n> Sets the transient DC offset voltage
:SLEW
[:IMMediate] <n> | INFinity Sets the voltage slew rate
:MODE <mode> Sets voltage slew mode (FIX | STEP | PULS | LIST)
:TRIGgered <n> | INFinity Sets the transient voltage slew rate
:PROTection
[:LEVel] <n> Sets the overvoltage protection threshold
:STATe <bool> Sets the overvoltage protection state
:SENSe | :ALC
:DETector <type> Sets the sense detector (RTIM | RMS)
:SOURce <source> Sets voltage sense source (INT | EXT)
:SLEW
[:IMMediate] <n> | INFinity Sets the voltage slew rate
:MODE <mode> Sets voltage slew mode (FIX | STEP | PULS | LIST)
:TRIGgered <n> | INFinity Sets the transient voltage slew rate

Table of Contents

Other manuals for Keysight Technologies 6811C

Related product manuals