Language Dictionary 3
Keysight Models 6811C, 6812C, and 6813C Programming Guide 103
Output Subsystem Commands
This subsystem controls the main outputs, the signal outputs, the power-on state,
and the output protection function of the ac source.
Subsystem syntax
OUTPut
[:STATe] <bool> Enable/disable output voltage, current, power, etc.
:COUPling <coupling> Enables AC or DC output coupling (AC | DC)
:DFI
[:STATE] <bool> Enable/disable DFI output
:SOURce <source> Selects an event source (QUES | OPER | ESB | RQS | OFF)
:IMPedance
[:STATE] <bool> Enable/disable output impedance programming
:REAL <n> Sets resistive part of output impedance
:REACtive <n> Sets inductive part of output impedance
:PON
:STATe <state> Set power-on state (RST | RCL0)
:PROTection
:CLEar Reset latched protection
:DELay <n> Delay after programming/before protection
:RI
:MODE <mode> Set remote inhibit input (LATC | LIVE | OFF)
:TTLTrg
[:STATE] <bool> Enable/disable trigger out drive
:SOURce <source> Selects a TTLTrg source (BOT | EOT | LIST)

Table of Contents

Other manuals for Keysight Technologies 6811C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies 6811C and is the answer not in the manual?

Keysight Technologies 6811C Specifications

General IconGeneral
BrandKeysight Technologies
Model6811C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals