Keysight Models 6811C, 6812C, and 6813C Programming Guide 109
OUTPut:RI:MODE
This command selects the mode of operation of the Remote Inhibit protection.
The following modes can be selected:
– LATChing: A TTL low at the RI input latches the output in the protection
shutdown state, which can only be cleared by OUTPut:PROTection:CLEar.
– LIVE: The output state follows the state of the RI input. A TTL low at the RI
input turns the output off; a TTL high turns the output on.
– OFF: The instrument ignores the RI input.
OUTPut:TTLTrg
This command enables or disables the ac source Trigger Out signal, which is
available at a BNC connector on the rear of the instrument.
Command syntax OUTPut:RI:MODE <mode>
Parameters LATChing | LIVE | OFF
*RST value OFF
Examples
OUTP:RI:MODE LIVE
Query syntax OUTPut:RI:MODE?
Returned parameters <CRD>
Related commands OUTP:PROT:CLE
Command syntax OUTPut:TTLTrg[:STATe] <bool>
Parameters 0 | 1 | OFF | ON
*RST value OFF
Examples
OUTP:TTLT 1 OUTP:TTLT ON
Query syntax OUTPut:TTLTrg[:STATe]?
Returned parameters 0 | 1
Related commands OUTP:TTLT:SOUR

Table of Contents

Other manuals for Keysight Technologies 6811C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies 6811C and is the answer not in the manual?

Keysight Technologies 6811C Specifications

General IconGeneral
BrandKeysight Technologies
Model6811C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals