3 Language Dictionary
94 Keysight Models 6811C, 6812C, and 6813C Programming Guide
MEASure:POWer:AC:REACtive?
FETCh:POWer:AC:REACtive?
These queries return the reactive power being sourced at the output terminals in
volt-amperes reactive (VAR). Reactive power is computed as:
MEASure:POWer:AC:PFACtor?
FETCh:POWer:AC:PFACtor?
These queries return the output power factor. The power factor is computed as:
Query syntax MEASure:[SCALar]:POWer:AC:REACtive?
FETCh:[SCALar]:POWer:AC:REACtive?
Parameters None
Examples
MEAS:POW:AC:REAC? FETC:POW:AC:REAC?
Returned parameters <NR3>
Related commands MEAS:POW:AC:APP? MEAS:POW:PFAC?
VAR Apparent Power()
2
Real Power()
2
()=
Query syntax MEASure:[SCALar]:POWer:AC:PFACtor?
FETCh:[SCALar]:POWer:AC:PFACtor?
Parameters None
Examples
MEAS:POW:AC:PFAC? FETC:POW:AC:PFAC?
Returned parameters <NR3>
Related commands MEAS:POW:AC:APP? MEAS:POW:REAC?