3 Language Dictionary
120 Keysight Models 6811C, 6812C, and 6813C Programming Guide
CURRent:PEAK:MODE
This command determines how the peak current limit is controlled during a
triggered output transient. The choices are as follows:
– FIXed: The peak current limit is unaffected by a triggered output transient.
– STEP: The peak current limit is programmed to the value set by
CURRent:PEAK:TRIGgered when a triggered transient occurs.
– PULSe: The peak current limit is changed to the value set by
CURRent:PEAK:TRIGgered for a duration determined by the pulse commands.
– LIST: The peak current limit is controlled by the peak current list when a
triggered transient occurs.
Command syntax [SOURce:]CURRent:PEAK:MODE <mode>
Parameters FIXed | STEP | PULSe | LIST
*RST value FIXed
Examples
CURR:PEAK:MODE FIX
Query syntax [SOURce:]CURRent:PEAK:MODE?
Returned parameters <CRD>