3 Language Dictionary
78 Keysight Models 6811C, 6812C, and 6813C Programming Guide
Measurement Subsystem (Arrays) Commands
This subsystem lets you retrieve arrays containing measurements data. Only
current and voltage measurements are stored in an array. Two measurement
commands are available: MEASure and FETCh. MEASure triggers the acquisition
of new data before returning the readings from the array. FETCh returns previously
acquired data from the array.
For Keysight 6811C/6812C/6813C Option 020 only, all standard ac source
MEASure or FETCh functions are available for the Main Output of the ac source as
well as the Power Analyzer input. The SENSe:NSELect command selects the
measurement source that will return data.
Subsystem syntax
MEASure | FETCh
:ARRay
:CURRent
[:DC]? Returns the digitized instantaneous current
:HARMonic
[:AMPLitude]? Returns amplitudes of the first 50 harmonics
:PHASe? Returns phase angles of the first 50 harmonics
:VOLTage
[:DC]? Returns the digitized instantaneous voltage
:HARMonic
[:AMPLitude]? Returns amplitudes of the first 50 harmonics
:PHASe? Returns phase angles of the first 50 harmonics