Keysight Models 6811C, 6812C, and 6813C Programming Guide 123
Source Subsystem (Frequency) Commands
This subsystem programs the output frequency of the ac source.
Subsystem syntax
FREQuency
This command sets the frequency of the output waveform.
[SOURce:]
FREQuency
[:CW | :IMMediate] <n> Sets the frequency
:MODE <mode> Sets frequency mode (FIX | STEP | PULS | LIST)
:SLEW
[:IMMediate] <n> | INFinity Sets the frequency slew rate
:MODE <mode> Sets frequency slew mode (FIX | STEP | PULS | LIST)
:TRIGgered <n> | INFinity Sets the triggered frequency slew rate
:TRIGgered <n> Sets the triggered frequency
Command syntax [SOURce:]FREQuency[:CW | :IMMediate] <NRf+>
Parameters MINimum | MAXimum |
0.001 to 1000 (6811C/6812C/6813C except Option 019)
0.001 to 100 (6813C Option 019)
Unit Hz (hertz)
*RST value 60
Examples
FREQ 50
Query syntax [SOURce:]FREQuency[:CW | :IMMediate]?
Returned parameters <NR3>
Related commands FREQ:MODE FREQ:SLEW

Table of Contents

Other manuals for Keysight Technologies 6811C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies 6811C and is the answer not in the manual?

Keysight Technologies 6811C Specifications

General IconGeneral
BrandKeysight Technologies
Model6811C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals