3 Language Dictionary
218 Keysight Models 6811C, 6812C, and 6813C Programming Guide
*TRG
This command generates a trigger to any subsystem that has BUS selected as its
source (for example, TRIG:SOUR BUS). The command has the same affect as the
Group Execute Trigger (<GET>) command.
*TST?
This query causes the ac source to do a self-test and report any errors.
Command syntax *TRG
Parameters None
Related commands ABOR INIT TRIG:IMM
Query syntax *TST?
Parameters None
Returned parameters <NR1> 0 indicates the ac source has passed self-test.
Non-zero indicates an error code
(refer to Appendix C, "Error Messages")