EasyManuals Logo

Keysight Technologies 6811C Programming Guide

Keysight Technologies 6811C
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
3 Language Dictionary
62 Keysight Models 6811C, 6812C, and 6813C Programming Guide
CALibrate:LEVel
CALibration:LEVel
This command can only be used in calibration mode. It is used to advance to the
next state in the calibration sequence.
CALibrate:PASSword
CALibration:PASSword
This command can only be used in calibration mode. It allows you to change the
calibration password. A new password is automatically stored in non-volatile
memory and does not have to be stored with CALibrate:SAVE. If the password is
set to 0, password protection is removed and the ability to enter the calibration
mode is unrestricted.
Command syntax CALibrate:LEVel <level>
CALibration:LEVel <level>
Parameters P1 | P2 | P3 | P4
Examples
CAL:LEV P2
Related commands CAL:STAT CAL:SAVE
Command syntax CALibrate:PASSword <NRf>
CALibration:PASSword <NRf>
Parameters 0 (default)
Examples
CAL:PASS 6812 CAL:PASS 02.1997
Related commands CAL:STAT CAL:SEC:CODE

Table of Contents

Other manuals for Keysight Technologies 6811C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies 6811C and is the answer not in the manual?

Keysight Technologies 6811C Specifications

General IconGeneral
BrandKeysight Technologies
Model6811C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals