EasyManuals Logo

Keysight Technologies 6811C Programming Guide

Keysight Technologies 6811C
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
3 Language Dictionary
86 Keysight Models 6811C, 6812C, and 6813C Programming Guide
MEASure:CURRent?
FETCh:CURRent?
These queries return the DC component of the output current being sourced at
the output terminals.
MEASure:CURRent:AC?
FETCh:CURRent:AC?
These queries return the AC component rms current being sourced at the output
terminals.
Query syntax MEASure:[SCALar]:CURRent[:DC]?
FETCh:[SCALar]:CURRent[:DC]?
Parameters None
Examples
MEAS:CURR? FETC:CURR?
Returned parameters <NR3>
Related commands MEAS:VOLT? MEAS:CURR:AC?
Query syntax MEASure:[SCALar]:CURRent:AC?
FETCh:[SCALar]:CURRent:AC?
Parameters None
Examples
MEAS:CURR:AC? FETC:CURR:AC?
Returned parameters <NR3>
Related commands MEAS:VOLT:AC? MEAS:CURR?