EasyManuals Logo

Keysight Technologies 6811C Programming Guide

Keysight Technologies 6811C
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #267 background imageLoading...
Page #267 background image
Programming Examples 5
Keysight Models 6811C, 6812C, and 6813C Programming Guide 267
Servicing questionable status events
This example assumes you want a service request generated whenever the ac
source's overvoltage, overcurrent, or overtemperature circuits have tripped. From
Figure 5-5, note the required path for Questionable Status conditions at bits 0, 1,
and 4 to generate a service request (RQS) at the Status Byte register. The required
register programming is as follows:
Step 1 Program the Questionable Status PTR register to allow a positive
transition at bits 0, 1, or 4 to be latched into the Status Event register.
Use:
STATus:QUEStionable:PTR 19 (1 + 2 + 16 = 19)
Step 2 Program the Questionable Status Enable register to allow the latched
events to be summed into the QUES summary bit. Use:
STATus:QUEStionable:ENABle 19
Step 3 Program the Service Request Enable register to allow the QUES
summary bit from the Status Byte register to generate RQS. Use:
*SRE 8
Step 4 When you service the request, read the event register to determine
which Questionable Status Event register bits are set and clear the
register for the next event. Use:
STATus:QUEStionable:EVENt?

Table of Contents

Other manuals for Keysight Technologies 6811C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies 6811C and is the answer not in the manual?

Keysight Technologies 6811C Specifications

General IconGeneral
BrandKeysight Technologies
Model6811C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals