EasyManuals Logo

Keysight x-series User Reference Guide

Keysight x-series
1138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #450 background imageLoading...
Page #450 background image
8 Frequency Scan Measurement
Meas Setup
By Time
Specifies that the elements in the signal list will be sorted based on time.
Key Path
Meas Setup, Signal List, Sort Signals
Example CALC:FSC:SLIS:SORT:TYPE TIME
Initial S/W Revision A.07.00
Sort Order
Chooses between ascending and descending sort order.
Key Path
Meas Setup, Signal List, Sort Signals
Remote Command
:CALCulate:FSCan:SLISt:SORT:ORDer ASCending |DESCending
:CALCulate:FSCan:SLISt:SORT:ORDer?
Example CALC:FSC:SLIS:SORT:ORD DESC
CALC:FSC:SLIS:SORT:ORD
Dependencies This key is grayed out when a scan sequence is running. If the grayed out key is pressed, an advisory
message is generated. If the equivalent SCPI command is sent, this same message is generated as
part of a “–221, Settings conflict” warning.
Couplings Selecting the sort order (pressing the key or sending the equivalent SCPI command) will turn on the
Auto Sort state, even if that sort order was already selected.
Preset ASCending
State Saved Saved in instrument state.
Initial S/W Revision A.07.00
Auto Sort
If this is turned on, the measurement will perform signal sorting based on the sorting order and sorting type
selected before each new signal is added. Otherwise, the signal will be added into the signal list in
descending order of the trace amplitude level.
Key Path
Meas Setup, Signal List, Sort Signals
Remote Command
:CALCulate:FSCan:SLISt:SORT:AUTO ON|OFF|1|0
:CALCulate:FSCan:SLISt:SORT:AUTO?
Example CALC:FSC:SLIS:SORT:AUTO 1 Turn on auto sorting
CALC:FSC:SLIS:SORT:AUTO?
Notes If Scan Sequence is set to Remeasure, the signal in the list will only be auto sorted when a
Remeasure is completed.
Dependencies This key is grayed out when a scan sequence is running. If the grayed out key is pressed, an advisory
message is generated. If the equivalent SCPI command is sent, this same message is generated as
part of a “–221, Settings conflict” warning.
450 EMI Receiver Mode Reference

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)

Related product manuals