11 APD Measurement
Meas Setup
Measure
Specifies the signal coverage for the automated APD measurement.
Key Path
Meas Setup
Remote Command
[:SENSe]:APD:MEAS ALL|MARKed
[:SENSe]:APD:MEAS?
Example APD:MEAS ALL
APD:MEAS?
Notes ALL = All Signals
MARKed = Marked Signals
Preset ALL
State Saved Saved in instrument state.
Range All Signals| Marked Signals
Readback All Signals| Marked Signals
Initial S/W Revision A.13.00
Limits
Opens the Limit Lines menu that contains keys to control limit lines of the current measurement.
Key Path
Meas Setup
State Saved Saved in instrument state.
Initial S/W Revision A.13.00
Select Limit
Specifies the selected limit. The term selected limit” is used throughout this document to specify which
limit will be affected by the functions.
Key Path
Meas Setup, Limits
Notes Front panel only. The selected limit is remembered even when not in the Limit Menu.
Currently, there is only 1 limit line in this measurement. Limit line choices 2 through 6 will be grayed
out.
Preset Limit 1
State Saved Saved in instrument state.
Initial S/W Revision A.13.00
EMI Receiver Mode Reference 941

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)

Related product manuals