10 Monitor Spectrum Measurement
View/Display
Meters RBW Lines
When Meters RBW Lines is turned on, two blue vertical lines appear on the display, equal distances from
the center of the graticule. Their spacing matches the current setting for the Meters RBW as shown below.
If the Meters RBW is wider than the span of the Monitor Spectrum display, these lines are not shown.
Key Path
View Display
Remote Command
:DISPlay:MONitor:RBWLines[:STATe] ON|OFF|1|0
:DISPlay:MONitor:RBWLines[:STATe]?
Example DISP:MON:RBWL ON
DISP:MON:RBWL?
Preset OFF
State Saved Saved in instrument state
Initial S/W Revision A.14.50
Example Views
Below are the views with Expand Meters Off (top) and Expand Meters on (bottom)
888 EMI Receiver Mode Reference

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)