8 Frequency Scan Measurement
Meas Setup
[:SENSe]:FSCan:SCAN[1]|2|...|10:POWer:GAIN[:STATe]?
Example FSC:SCAN4:POW:GAIN ON Turn on Internal Preamp of Range 4.
FSC:SCAN4:POW:GAIN?
Dependencies Preamp is not available on all hardware platforms. If the preamp is not present or is unlicensed, the
key is not shown.
This key is grayed out during multi range scanning. If the grayed out key is pressed, an advisory
message is generated. If the equivalent SCPI command is sent, this same message is generated as
part of a “–221, Settings conflict; Function not available while running multirange scan” warning.
This key is grayed out during final measurement. If the grayed out key is pressed, an advisory
message is generated. If the equivalent SCPI command is sent, this same message is generated as
part of a “–221, Settings conflict” warning.
Preset OFF
State Saved Saved in instrument state.
Range On|Off
Initial S/W Revision A.07.00
Key Path
Meas Setup, Scan Table
Remote Command
[:SENSe]:FSCan:SCAN[1]|2|...|10:POWer:GAIN:BAND LOW|FULL
[:SENSe]:FSCan:SCAN[1]|2|...|10:POWer:GAIN:BAND?
Example FSC:SCAN3:POW:GAIN:BAND LOW Set Range 3 to Low band Preamp.
FSC:SCAN3:POW:GAIN:BAND?
Dependencies Preamp is not available on all hardware platforms. If the preamp is not present or is unlicensed, the
key is not shown.
If a POW:GAIN:BAND FULL command is sent when a low band preamp is available, the preamp band
parameter is set to LOW instead of FULL, and an Option not installed message is generated.
This key is grayed out during multi range scanning. If the grayed out key is pressed, an advisory
message is generated. If the equivalent SCPI command is sent, this same message is generated as
part of a “–221, Settings conflict; Function not available while running multirange scan” warning.
This key is grayed out during final measurement. If the grayed out key is pressed, an advisory
message is generated. If the equivalent SCPI command is sent, this same message is generated as
part of a “–221, Settings conflict” warning.
Preset LOW
State Saved Saved in instrument state.
Range Low Band|Full Range
Initial S/W Revision A.07.00
Remote Command
[:SENSe]:SCAN[1]|2|...|10:INPut:GAIN[:STATe] ON|OFF|1|0
[:SENSe]:SCAN[1]|2|...|10:INPut:GAIN[:STATe]?
Example SCAN5:INP:GAIN ON Turn on low band preamp in Range 5.
466 EMI Receiver Mode Reference

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)

Related product manuals