Configuration
7-6
L
EDSVS9332P-D21 EN 3.0
Configuration code
Configures the input with a signal source (e. g. terminal signal, control code, output of an FB, ...).
Inputs with identical codes are distinguished by the attached subcode (Cxxxx/1). These codes are
configured via the subcode.
It is not possible to connect an input with several signal sources.
Display code
Displays the current input value. Inputs with identical codes are distinguished by the attached
subcode (Cxxxx/1). These codes are displayed via the subcode.
Display codes cannot be processed.
Function
Represents the mathematical function as a block diagram (see Fig. 7-1).
Parameter setting code
Adaptation of the function or behaviour to the drive task. Possible settings are described in the text
editor and / or the line diagrams.
(E 7-20)
Output symbol
Designates the signal type. Connections with inputs of the same signal type are possible.
(E 7-4)
Each output is defined by a selection number. The selection numbers are divided into selection lists
(1 ... 4) according to the different signal types.
(E7-381 ff)
An output is linked to an input by the selection numbers.
Example:
(FCNT1, see Fig. 7-1)
FCNT1-OUT selection number 6400 (analog signal, selection list 1).
FCNT1-EQUAL selection number 6400 (digital signal, selection list 2).
Tip!
Only linked outputs can be configured.
Output name
Consists of the FB name and a designation. Outputs with the same function are distinguished by the
number that is added to the designation.