Function library
7-127
L
EDSVS9332P-D21 EN 3.0
CTRL
BRK-SET
C0459
BRK-OUT
C0450
C0451
BRK-Nx
C0458/1
BRK-QSP
BRK-M-STORE
BRK-CINH
BRK-M-SET
C0452
BRK-SIGN
C0458/1
SIGN
t
0
t
0
CINH
MCTRL-NACT
MCTRL-MACT
C0195
C0196
C0244
BRK
MCTRL-NSET2
Fig. 7-86 Holding brake (BRK)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
BRK-SET d C0459 bin C0451 2 1000 -
BRK-NX a C0458/1 dec [%] C0450 1 1000 Speed threshold from which the drive may
output the signal ”Close brake”. The signal
source for this i nput can be a control code,
a fixed value, or any other analog FB
output.
BRK-SIGN a C0458/2 dec [%] C0452 1 1000 Direction of the torque with which the drive
is to set up a torque against the brake. The
signal source for this input can be a control
code, a fixed value, or any other FB o utput.
BRK-M-SET a - dec [%] C0244 - 0.00 Holding torque of the DC injection brake
100 % = value of C0057
BRK-T-ACT a - dec C0195 - 99.9 Brake engaging time
BRK-T-RELEASE a - dec C0196 - 0.0 Brake application time
Function
The signals N-ACT, M-ACT, N-SET and BRK-Nx are processed as absolute values within the function
block.
7.5.29.1 Applying the brake
Purpose A HIGH-Signal at the BRK-SET input
activates the function. The BRK-QSP
output is simultaneously set to HIGH.
This signal can be used to decelerate
the drive to zero speed via a
deceleration ramp.
t
BRK-SET
MCTRL-NSET2
|
B
R
K
N
x
|
t
BRK-QSP
Function If the setpoint speed falls below the
value set at the BRK- Nx input, the
BRK-OUT output is set to HIGH. In order
to ensure a fail-safe design this signal
must be inverted at the output (e.g. via
C0118).
t
t
BRK-OUT
BRK-RSP
|BRK-Nx|
C0195
t
Show/Hide Bookmarks