Function library
7-37
L
EDSVS9332P-D21 EN 3.0
7.5.3.2 Absolute positioning
9300POS025
S 1S 2 S 3
H o m e p o s i t i o n
L i m i t p o s i t i o n
n e g a t i v e
C 1 2 2 4 C 1 2 2 3
E n d o f t r a v e l s w i t c h
p
o s i t i v e d i r e c t i o n
P O S - L I M - N E G P O S - L I M - P O SP O S - R E F - M A R K
E n d o f t r a v e l s w i t c h
n e
g
a t i v e d i r e c t i o n
L i m i t p o s i t i o n
p o s i t i v e
Fig. 7-16 Example of a machine with finite traversing range
Purpose
Use in applications with finite traversing range, e. g. in warehousing or handling machines.
Function
Set positioning mode (C1210) = 0 (default setting)
Before starting a positioning drive homing must be carried out (output POS-REF-OK = 1,
homing status C1284 = REF-OK). By homing the reference point of the measuring system to
the machine is determined
(E 7-49)
In the absolute positioning mode absolute and relative target positions can be approached.
There are two measuring systems
(E 7-39)
:
the machine measuring system and
the real measuring system
The travel range limit switches are located in front of the mechanical stops. They prevent the
drive from touching the stops.
Adjustable position limiting values (C1223, C1224) prevent the travel range limit switches from
being approached under normal operating conditions. A target position located outside the
position limiting value is not approached. In this case a fault is indicated (P04, P05).