Loading...
Function library
7-96
L
EDSVS9332P-D21 EN 3.0
7.5.19 Automation interface (AIF-IN)
Purpose
Interface for input signals of the plug-on fieldbus module (e.g. INTERBUS, PROFIBUS) for setpoints
and actual values as binary, analog, or phase information. Please observe the corresponding
Operating Instructions for the plug-on fieldbus module.
1 6 B i t
1 6 B i t
A I F - I N . W 2
A I F - I N . W 3
1 6 b i n a r y
s i g n a l s
1 6 B i t
L O W W o r d
1 6 B i t
H I G H W o r d
1 6 b i n a r y
s i g n a l s
1 6 B i t
A I F - I N . W 1
A I F - I N . B 1 5
A I F - I N . B 0
A I F - I N . D 1
A I F - C T R L . B 1 2
A I F - C T R L . B 1 3
A I F - C T R L . B 1 4
A I F - C T R L . B 1 5
B y t e 3 , 4B y t e 5 , 6
B y t e 7 , 8
A
u t o m a t i o n -
I n t e r f a c e X 1
A I F - I N
B i t 0
B i t 1 5
C o n t r o l w o r d
A I F - C T R L . B 0
A I F - C T R L . B 1
A I F - C T R L . B 2
A I F - C T R L . B 4
A I F - C T R L . B 5
A I F - C T R L . B 6
A I F - C T R L . B 7
D C T R L
Q S P
A I F - C T R L . B 3
D I S A B L E
A I F - C T R L . B 8
C I N H
A I F - C T R L . B 9
T R I P - S E T
A I F - C T R L . B 1 0
T R I P - R E S E T
A I F - C T R L . B 1 1
A I F - I N . B 1 4
A I F - I N . B 2
A I F - I N . B 3 1
A I F - I N . B 1 6
A I F - I N . B 3 0
A I F - I N . B 1 7
1 6 B i t
. . .. . .
C 0 8 5 7
C 0 8 5 6 / 1
C 0 8 5 6 / 2
C 0 8 5 5 / 1
C 0 8 5 5 / 2
C 0 8 5 6 / 3
C 1 1 9 7
1 6 B i t
L O W W o r d
1 6 B i t
H I G H W o r d
A I F - I N . D 2
C 0 1 3 6 / 3
AIF-IN
Fig. 7-51 Automation interface (AIF-IN)