Configuration
7-309
L
EDSVS9332P-D21 EN 3.0
7.6.3.15 Motor temperature monitoring OH8
Purpose
Motor protection
MONIT
MONIT-OH8
DIN44081
T1/ T2
Fig. 7-248 Motor temperature monitoring OH8
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
T1/T2 - - - - - - -
MONIT-OH8 d - - - - - -
Function
The signal OH8 is derived from the digital signal via the terminals T1, T2 next to the power terminals
UVW. The threshold and the hysteresis depend on the encoder system (DIN 44081) (see Chapter
4.2.10).
Stop!
When using this input as a motor protection: If the monitoring is set to WARNING or OFF, the motor
can be destroyed in case of further overload.
Features:
LECOM no.: 58, 2058
Reaction: TRIP, WARNING or OFF