EasyManua.ls Logo

Lenze 9300 - Motor Potentiometer (MPOT)

Lenze 9300
591 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function library
7-228
L
EDSVS9332P-D21 EN 3.0
7.5.63 Motor potentiometer (MPOT)
Purpose
The FB replaces a hardware motor potentiometer.
The motor potentiometer is used as an alternative setpoint source, which is controlled via two
terminals.


MPOT1















Fig. 7-176 Motor potentiometer (MPOT1)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
MPOT1-UP d C0269/1 bin C0267/1 2 1000 -
MPOT1-INACT d C0269/3 bin C0268 2 1000 -
MPOT1-DOWN d C0269/2 bin C0267/2 2 1000 -
MPOT1-OUT a - - - - -
Function
Control of the motor potentiometer:
MPOT1-UP = HIGH
The motor potentiometer approaches its upper limit value.
MPOT1-DOWN = HIGH
The motor potentiometer approaches its lower limit value.
MPOT1-UP = LOW and MPOT1-DOWN = LOW or
MPOT1-UP = HIGH and MPOT1-DOWN = HIGH:
The motor potentiometer does not change the output signal.