Function library
7-176
L
EDSVS9332P-D21 EN 3.0
7.5.44.1 Output signals to X10
A
B
Rechtslauf
A
B
Z
Z
Fig. 7-134 Signal sequence for CW rotation (definition)
The output signal corresponds to the simulation of an incremental encoder:
Track A, B and, if necessary, zero track as well as the corresponding inverted tracks are
output with tracks shifted by 90 degrees.
The levels are TTL-compatible.
Positive input values (CW rotation) result in the represented signal sequence.
With negative input values (CCW rotation) track B is leading track A by 90°.
The zero track is output according to the function set in C0540
With C0030 the encoder constant of the encoder simulation is set.
The function of the digital frequency output X10 is defined via C0540.
Stop!
C0540 = 0 to C0540 = 3 cannot be set if the connection to the digital frequency input DFIN X9 has
been established and C0025 > 10 has been selected.
C0540 Signal at X10
0 DFOUT-A N- IN is output at X10; zero trac k can be i nput externally
1 DFOUT-DF-IN is output at X10; zero track can be input externally
2 Encoder simulation of the resolver with zero track in resolver zero position (mounted on the motor)
3 Encoder simulation of the resolver with external input of the zero track (terminal X5/E5)
4 The signal at input X9 is electrically amplified and directly output (C0030 is without function)
5 The signal at input X8 is electrically amplified and directly output (C0030 is without function)