Function library
7-176
L
EDSVS9332P-D21 EN 3.0
7.5.44.1 Output signals to X10
A
B
Rechtslauf
A
B
Z
Z
Fig. 7-134 Signal sequence for CW rotation (definition)
•
The output signal corresponds to the simulation of an incremental encoder:
– Track A, B and, if necessary, zero track as well as the corresponding inverted tracks are
output with tracks shifted by 90 degrees.
– The levels are TTL-compatible.
•
Positive input values (CW rotation) result in the represented signal sequence.
•
With negative input values (CCW rotation) track B is leading track A by 90°.
•
The zero track is output according to the function set in C0540
•
With C0030 the encoder constant of the encoder simulation is set.
•
The function of the digital frequency output X10 is defined via C0540.
Stop!
C0540 = 0 to C0540 = 3 cannot be set if the connection to the digital frequency input DFIN X9 has
been established and C0025 > 10 has been selected.
C0540 Signal at X10
0 DFOUT-A N- IN is output at X10; zero trac k can be i nput externally
1 DFOUT-DF-IN is output at X10; zero track can be input externally
2 Encoder simulation of the resolver with zero track in resolver zero position (mounted on the motor)
3 Encoder simulation of the resolver with external input of the zero track (terminal X5/E5)
4 The signal at input X9 is electrically amplified and directly output (C0030 is without function)
5 The signal at input X8 is electrically amplified and directly output (C0030 is without function)