EasyManua.ls Logo

Lenze 9300 - Generate Parameter Set; Adapt Controller to the Mains

Lenze 9300
591 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
5-7
L
EDSVS9332P-C EN 3.0
5.6 Generate parameter set
Warning!
Do not change any settings of the controller that are not mentioned in this chapter. For more complex
positioning tasks use the System Manual.
The instructions for the generation of a parameter set inthis chapter are based on the default setting.
Proceed systematically when generating a parameter set:
1. Adapt controller to mains conditions.
2. Adapt controller to motor.
3. Enter machine parameters.
4. Enter parameters for manual control. (Afterwards, carry out a function test)
5. Enter parameters for traversing profile.
Tip!
Make a travel profile of your positioning task and determine as many positioning data as possible,
using this drawing.
(E 5-14)
5.6.1 Adapt controller to the mains
2
1
3
4
Fig. 5-3 Basic settings dialog box
Field
Command Function
1 Click on field Select values for the actual mains and operating conditions.
Show/Hide Bookmarks

Table of Contents

Other manuals for Lenze 9300

Related product manuals