Function library
7-77
L
EDSVS9332P-D21 EN 3.0
7.5.13.1 PS mode
Purpose
Selection which positioning or special function is to be carried out in the PS.
Function
GDC input: Dialog Programming
Factory setting: No positioning or special function
Input under PS mode (C1311):
Value Program functions
0 No positioning or special function
1 Absolute PS
2 Relative PS
3 Homing
4 Set homing value
5 Set position value to target position (C1312)
6 Absolute PS; TP positioning with E01
7 Absolute PS, TP positioning with E02
8 Absolute PS, TP positioning with E03
9 Absolute PS, TP positioning with E04
11 Relative PS, TP positioni ng with E01
12 Absolute PS, TP positioning with E02
13 Relative PS, TP positioni ng with E03
14 Relative PS, TP positioni ng with E04
16 Acceptance of home position (C1227)
30 Stand-by mode, cancel with STDBY-STP
31 Stand-by mode, cancel with TP E01 and traversing of the residual distance
32 Stand-by mode, cancel with TP E02 and traversing of the residual distance
33 Stand-by mode, cancel with TP E03 and traversing of the residual distance
34 Stand-by mode, cancel with TP E04 and traversing of the residual distance