Overview of the fault sources detected by the controller, and the corresponding reactions.
Display Meaning TRIP Message Warning FAIL-QSP off Code Notes
CCr System fault • - - - - -
CE0 Communication error (AIF) 9 - 9 - • C0126
CE1 Communication error at the process data input object
CAN-IN1 (time monitoring can be set under C0357/1)
9 - 9 - • C0591
CE2 Communication error at the process data input object
CAN-IN2 (time monitoring can be set under C0357/2)
9 - 9 - • C0592
Part E, E 8-5
CE3 Communication error at the process data input object
CAN-IN3 (time monitoring can be set under C0357/3)
9 - 9 - • C0593
CE4 BUS-OFF state (many communication errors occurred) 9 - 9 - • C0595
EEr External monitoring • 9 9 9 9 C0581 E 7-297
H05, H07 Internal error • - - - - -
H10 Sensor faul t: heat sink temperature • - - - 9
C0588
Part E, E 8-5
H11 Sensor fault: internal temperature • - - - 9
LP1 Motor phase failure detection (function block must be
entered in C0465)
9 - 9 - • C0597 E 7-299
LU Undervoltage - • - - - - E 7-300
NMAX Maximum speed exceeded (C0596) • - - - - - E 7-301
nErr Speed monitoring 9 9 9 9 • C0576 E 8-5
OC1 Short-circuit • - - - - - E 7-302
OC2 Earth fault • - - - - - E 7-303
OC5 I x t overload • - - - - - E 7-304
OH Heatsink temperature 1 (max. permissible, fixed) • - - - - - E 7-305
OH3 Motor temperature 1 (max. permissible, fixed) • - - - 9 C0583 E 7-306
OH4 Heatsink temperature 2 (adjustable; C0122) - - • - 9 C0582 E 7-307
OH7 Motor temperature 2 (can be set; code: C0121) - - • - 9 C0584 E 7-308
OH8 Motor temperature (fixed) via inputs T1/T2 9 - 9* - • C0585 E 7-309
OU Overvoltage in the DC bus - • - - - - E 7-310
P01 Limit switch nega tive = LOW 9 - - • - C1285/1
P02 Limit switch positive = LOW 9 - - • - C1285/2
Par
E,
8-5
P03 Following error - digital frequency > C0255 9 - • - 9 C0589 E 7-312
P04 Position limit negative exceeded 9 - - • - C1285/3
P05 Position limit positive exceeded 9 - - • - C1285/4
P06 No reference 9 - - • - C1287/1
P07 Parameter set mode absolute 9 - - • - C1291/1
Part E, E 8-5
P08 Actual offset out of range 9 - - • - C1291/2
P09 Impermissible programming 9 - - • - C1291/3
P12 Encoder range exceeded 9 - - • - C1288/1
P13 Phase overflow • - 9 - 9 C0590 E 7-313
P14 1. following error POS > C1218/1 9 - 9 • 9 C1286/1
P15 2. following error POS > C1218/2 9 - 9 • 9 C1286/2
P16 Sync error 9 - 9 • 9 C1290/1
P17 TP control error 9 - 9 • 9 C1289/1
Part E, E 8-5
P18 Internal limitation 9 - • 9 9 C1289/2
PEr Program error • - - - - -
PI Fault during initialization • - - - - -
PR0 General fault in parameter sets • - - - - - E 7-314
PR1 Fault in parameter set 1 • - - - - - E 7-315
Sd2 Resolver error • - 9* - 9 C0586 E 7-316