EasyManua.ls Logo

Lenze 9300 - Scaling of Phintx-OUT

Lenze 9300
591 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function library
7-252
L
EDSVS9332P-D21 EN 3.0
7.5.70.2 Scaling of PHINTx-OUT
Mathematic description of PHINTx-OUT:
PHINTxOUT[inc] = PHINTxIN[rpm] t[s] 65536[incUmdr.]
t = integration time
Example:
You want to determine the count of the integrator with a certain speed at the input and a certain
integration time.
Given values:
PHINTx-IN = 1000 rpm
t=10s
Start value of the integrator = 0
Solution:
Conversion of PHINTx-IN:
1000 rpm =
1000 rev.
60 s
Calculation of PHINTx-OUT:
PHINTx OUT =
1000 rev.
60 s
10 s
65536 inc
rev.
= 10922666 inc
Show/Hide Bookmarks

Table of Contents

Other manuals for Lenze 9300

Related product manuals