Function library
7-157
L
EDSVS9332P-D21 EN 3.0
7.5.36 Analog-phase converter (CONVAPH)
Conversion of an analog value into a phase signal.
CONVAPH1
CONVAPH1
CONVAPH1-OUT
C1594
CONVAPH1-IN
C1593
C1591
C1590
± 2
30
-1
Signal Source Note
Name Type DIS DIS format CFG List
CONVAPH1-IN a C1594 dec C1593 1 -
CONVAPH1-OUT ph - - - - Limited to ±2
30
-1
Function
Conversion with adaptation through multiplier and divisor.
Conversion according to the formula:
CONVAPH1OUT = CONVAPH1IN
C1590
C1591
16384
100%
CONVAPH2
CONVAPH2
CONVAPH2-OUT
C1599
CONVAPH2-IN
C1598
C1596
C1595
± 2
30
-1
Signal Source Note
Name Type DIS DIS format CFG List
CONVAPH2-IN a C1599 dec C1598 1 -
CONVAPH2-OUT ph - - - - Limits to ±2
30
-1
Function
Conversion with adaptation using multiplier and divisor.
The conversion is performed according to the formula:
CONVAPH1 OUT = CONVAPH1 IN
C1595
C1596
16384
100%