7.5.13.5 Stand-by mode
Purpose
Implementation of a Flying saw, with additional function block interconnection (on request).
Enables the changeover between positioning and another setpoint source, e.g. master
frequency of a main drive.
DFSET
DFSET-NOUT
+
-
DFSET-PSET
DFSET-POUT
+
+
C0253
DFSET-PSET2
C0105
C0908
MCTRL-PHI-SET
MCTRL-N-SET
MCTRL
C0906/1
MCTRL-N/M-SWT
MCTRL-HI-M-LIM
MCTRL-LO-M-LIM
MCTRL-I-SET
MCTRL-I-LOAD
MCTRL-QSP
C0893
C0892
C0899
C0900
C0902
C0901
C0890
C0894
MCTRL-P-ADAPT
C0906/9
C0903
POS-NOUT
POS-N-IN
C1362/4
C1363/4
POS-P-IN
C1364/3
C1365/3
0
1
0
1
POS-POUT
POS-MOUT
0
1
POS-M-IN
C1362/6
C1363/6
Lsoll
Nsoll
POS
POS-STDBY-ACT
9300POS010
Fig. 7-38 Stand-by operation with selection through master frequency
Function
Stand-by operation is only possible in manual operation.
PS mode (C1311): Select 30...34 (stand-by operation and signal source for abort).
In PS, stand-by operation is executed instead of positioning. As long as stand-by operation is
active, positioning or special function in the PS is not completed. The following PS functions
are only processed when the stand-by operation is terminated (see diagrams).
After having started the stand-by operation, the drive is accelerated or decelerated to the
external speed setpoint at POS-N-N due to positioning. The profile parameters of the PS
apply.
When reaching the speed the external setpoint inputs (POS-N-IN, POS-P-IN) are used. From
now on, the position setpoint (POS-SETPOS) equals the actual position value (POS-ACTPOS):
POS-STDBY-ACT = HIGH