Function library
7-121
L
EDSVS9332P-D21 EN 3.0
7.5.28.3 ”CANCEL” function
The identification for ”CANCEL” at the inputs BCDx-DATAx results in the following state:
Input/output Signal Function
BCDx-EOT HIGH Switches
BCDx-NEW-DATA HIGH Switches
- - Sets BCDs which are not yet read to zero and stops reading.
- - The inputs BCDx-DATAx expect the sign as the next BCD.
7.5.28.4 ”RESET” function
The identification for ”RESET” at the inputs BCDx-DATAx results in the following state:
Function Input/output Signal
Switches BCDx-EOT LOW
Switches BCDx-DATA-FLT LOW
Switches for a millisecond BCDx-NEW-DATA LOW
Switches if BCDx-FAIL-IN = LOW is switched at the same time (internal OR link). BCDx-FAIL LOW
Switches if BCDx-BUSY-IN = LOW is switched at the same time (internal OR link). BCDx-BUSY LOW
The inputs BCDx-DATAx expect the sign as the next BCD. - -
The BCD read la st remains and can be transmitted to the target code. - -