7.5.27 Changeover switch for analog signals (ASW)
Purpose
This FB changes between two analog signals.
Therefore, it is possible to change e.g. during winding between an initial diameter and a calculated
diameter.
ASW1-IN1
C0812/1
1
0
C0812/2
ASW1-SET
ASW1-IN2
ASW1
ASW1-OUT
C0813
C0810/1
C0810/2
C0811
Fig. 7-75 Changeover switch for analog signals (ASW1)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
ASW1-IN1 a C0812/1 dec [%] C0810/1 1 55 -
ASW1-IN2 a C0812/2 dec [%] C0810/2 1 1000 -
ASW1-SET d C0813 bin C0811 2 1000 -
ASW1-OUT a - - - - - -
ASW2-IN1
C0817/1
1
0
C0817/2
ASW2-SET
ASW2-IN2
ASW2
ASW2-OUT
C0818
C0815/1
C0815/2
C0816
Fig. 7-76 Changeover switch for analog signals (ASW2)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
ASW2-IN2 a C0817/1 dec [%] C0815/1 1 1000 -
ASW2-IN1 a C0817/2 dec [%] C0815/2 1 1000 -
ASW2-SET d C0818 bin C0816 2 1000 -
ASW2-OUT a - - - - - -
A S W 3 - I N 1
C 1 1 6 2 / 1
1
0
C 1 1 6 2 / 2
A S W 3 - S E T
A S W 3 - I N 2
A S W 3
A S W 3 - O U T
C 1 1 6 3
C 1 1 6 0 / 1
C 1 1 6 0 / 2
C 1 1 6 1
Fig. 7-77 Changeover switch for analog signals (ASW3)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
ASW3-IN2 a C1162/1 dec [%] C1160/1 1 1000 -
ASW3-IN1 a C1162/2 dec [%] C1160/2 1 1000 -
ASW3-SET d C1163 bin C1161 2 1000 -
ASW3-OUT a - - - - - -