Function library
7-114
L
EDSVS9332P-D21 EN 3.0
A S W 4 - I N 1
C 1 1 6 7 / 1
1
0
C 1 1 6 7 / 2
A S W 4 - S E T
A S W 4 - I N 2
A S W 4
A S W 4 - O U T
C 1 1 6 8
C 1 1 6 5 / 1
C 1 1 6 5 / 2
C 1 1 6 6
Fig. 7-78 Changeover switch for analog signals (ASW4)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
ASW4-IN2 a C1167/1 dec [%] C1165/1 1 1000 -
ASW4-IN1 a C1167/2 dec [%] C1165/2 1 1000 -
ASW4-SET d C1168 bin C1166 2 1000 -
ASW4-OUT a - - - - - -
Function
This FB is controlled via a binary input. Depending on the input signal, different signals are sent to
the output:
•
If a HIGH signal is applied at the binary input, the signal which is applied at the ASWx-IN2
inputissenttotheoutput.
•
If a LOW signal is applied, the signal which is applied at the ASW-IN2 input is sent to the
output.