EasyManua.ls Logo

Lenze 9300 - Delay Elements (DIGDEL)

Lenze 9300
591 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function library
7-189
L
EDSVS9332P-D21 EN 3.0
7.5.47 Delay elements (DIGDEL)
Purpose
This function is used to delay digital signals. These operations can be used for the control of functions
or the generation of status information.
t
0
DIGDEL1-IN
C0724
DIGDEL1-OUT
DIGDEL1
C0721
C0720
C0723
Fig. 7-142 Delay element (DIGDEL1)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
DIGDEL1-IN d C0724 bin C0723 2 1000 -
DIGDEL1-OUT d - - - - - -
t
0
DIGDEL2-IN
C0729
DIGDEL2-OUT
DIGDEL2
C0726
C0725
C0728
Fig. 7-143 Delay element (DIGDEL2)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
DIGDEL2-IN d C0729 bin C0728 2 1000 -
DIGDEL-OUT d - - - - - -
Function
You can select the following functions under C0720 (DIGDEL1) and C0725 (DIGDEL2):
on-delay
dropout delay
general delay
Show/Hide Bookmarks

Table of Contents

Other manuals for Lenze 9300