7.5.8.3 Referencing status (POS-REF-OK)
The referencing status is indicated via the function block output POS-REF-OK and displayed under
C1284.
The referencing status is displayed as Reference known when the measuring systems have a
defined reference to the machine. Absolute positioning
(E 7-37)
or
(E 7-38)
is only possible after a
defined reference has been created.
The output POS-REF-OK is set by
homing is completed,
the program function Set reference is set,
the absolute value encoder is selected as position feedback (C0490 = 4).
Set Fb input POS-ABS-SET = 1.
C1210 = 2 (absolute positioning with saving)
The output POS-REF-OK is reset by
Start of homing
Description of the following codes:
C0011 (Nmax)
C0490 (feedback system for the position controller)
C1202 (Gearbox factor, numerator)
C1203 (Gearbox factor, denominator)
C1204 (Feed constant)
C1207/1(Position encoder gearbox factor, numerator)
C1207/2 (Position encoder gearbox factor, denominator)
C1210 (Positioning mode)
The following errors occur:
NMAX (limit speed of C0596)
P12 (encoder limit exceeded)
SD2 (resolver error) if resolver has been selected as position feedback system (C0490=0),
SD7 (absolute value encoder).
In relative positioning mode (C1210=1) if Prg-reset is carried out during a running positioning
process.