Commissioning
5-9
L
EDSVS9332P-C EN 3.0
5.6.3 Enter machine parameters
1
2
3
4
5
6
7
Fig. 5-5 ”Basic settings” dialog box
Field
Command Function
1 Click on field ”Gearbox numerator” Enter denomina tor for the gearbox ratio.
n
2 Click on field ”Gearbox denominator” Enter numera tor for the gearbox ratio.
i
=
n
Gearbox output
3 Click on field ”Feed constant” Enter feed of the spindle. The value results from the number of
units (e. g. mm) being moved forward
during one rotation at the gearbox output
side.
4 Click on field ”Speed (n-max)” Enter upper speed l imit of the motor
5 Click on field ”Velocity (v-max)” Enter fastest tra versing velocity of the machine
6 Click on field ”Acceleration (a-max)” Maximum permissible ac celeration (with interference or during approach to travel
range limit switches a-max cannot be activated.
7 Click on field ”QSP ramp” Time from release of fault or a pproach to a travel range limit switch to machine
standstill.