7.5.76.3 Dead time
This function is available only for the FB SP2.
Purpose
Delayed triggering of subsequent machine parts (e.g. spray jets).
Function
The dead time is entered via C1657.
The setting is possible for SP2-STAT1 ... SP2-STAT4 only.
Assignment of the code to the outputs:
Code Subcode Output FB SP2
C1657
1 SP2-STAT1
2 SP2-STAT2
3 SP2-STAT3
4 SP2-STAT4
The dead time acts on switching points and hysteresis.
Positive dead time
I N x - 1 I N x - 2
S P 2 - L - I N
S
P 2 - S T A T x
H I G H
L O W
T
d e a d
T
d e a d
T r a v e l d i r e c t i o n
I N x - 1 I N x - 2
S P 2 - L - I N
S
P 2 - S T A T x
H I G H
L O W
T
T o t
T
T o t
T r a v e l d i r e c t i o n
( p o s i t i v e d e a d t i m e )
( p o s i t i v e d e a d t i m e )
Fig. 7-217 Function of the positive dead time with different travel directions
With a positive dead time, the drive reacts earlier by the time period set.