Function library
7-186
L
EDSVS9332P-D21 EN 3.0
Function
Setpoint conditioning with stretch and gearbox factor
Processing of correction values
Synchronising to zero track or touch probe (for resolver feedback touch probe only)
7.5.46.1 Setpoint conditioning with stretching and gearbox factor
Stretching factor
Defines the ratio between the drive and the setpoint.
The stretching factor evaluates the setpoint at DFSET-IN. DFSET-POUT outputs the result.
The stretching factor results from numerator and denominator.
Numerator is variable from analog signal source or fixed value by the code.
Input of the denominator under C0533.
Relationship:
DFSETPOUT = DFSETIN
DFSETVPDIV
C0533
Gearbox factor
Defines the transmission ratio of the drive. Enter the ratio of the drive.
The gearbox factor evaluates the setpoint at DFSET-IN multiplied by the stretching factor.
DFSET-NOUT outputs the result.
The gearbox factor results from numerator and denominator.
Numerator is variable from analog signal source or fixed value by the code.
Input of the denominator under C0033.
Relationship:
DFSET NOUT = Stretching factor
DFSET RAT DIV
C0033
DFSETNOUT = DFSETIN
DFSETVPDIV
C0533
DFSETRATDIV
C0033