EasyManua.ls Logo

Lenze 9300 - Phase Displacement; Time Slot for Synchronisation Via Terminal

Lenze 9300
591 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function library
7-273
L
EDSVS9332P-D21 EN 3.0
7.5.79.3 Phase displacement
Phase displacement for synchronisation via system bus (SYNC TIME)
Code Value Function
C1122 0 ...10.000 µs
C1120 = 1
Phase displacement between the sync telegram and the start of the internal c ontrol program.
The parameters are set automatic a lly depending on the parameter setting of the system bus (CAN).
C1120 = 2
C1122 has no effect.
Phase displacement for synchronisation via terminal (PHASESHIFT)
Code Value Function
C1123/1 -1.000 ms
to
+1.000 ms
C1120 = 1
C1123/1 has no effect.
C1120 = 2
Phase di spl a cement between the sync signal and the start of the i nternal control program (e. g. for
compensating the effects of signal propagation delays /dead times for the sync signal of the single
slave drives).
7.5.79.4 Time slot for synchronisation via terminal
Code Value Function
C1123/2 0 ... 1.000 ms
C1120 = 1
C1123/2 has no effect.
C1120 = 2
Definition of a ”time slot” for the LOW-HIGH edges of the sync signal for the slave (defined via
C1121/1).
If the sync signal sent by the master is inside the ”time slot”, the SYNC1-STAT is switched to HIGH.
S Y N C - C y c l e ( C 1 1 2 1 / 1 )
S Y N C - W i n d o w ( C 1 1 2 3 / 2 )
S Y N C - S i g n a
l
Fig. 7-223 Time slot for the LOW-HIGH edges of the sync signal
Tip!
A jitter of up to ±200 µs on the LOW-HIGH edges of the sync signal is permissible. The size of the
jitter affects the parameter setting of the time slot.
Show/Hide Bookmarks