Function library
7-269
L
EDSVS9332P-D21 EN 3.0
Function
•
Possible axis synchronisations (chapter 7.5.79.1)
•
Cycle times (chapter 7.5.79.2)
•
Phase displacement (chapter 7.5.79.3)
•
Synchronisation window for synchronisation via terminal (SYNC WINDOW) (chapter 7.5.79.4)
•
Correction value of phase controller (SYNC CORRECT) (chapter 7.5.79.5)
•
Fault indications (chapter 7.5.79.6)
•
Configuration examples (chapter 7.5.79.7)
•
Scaling (chapter 7.5.79.8)
7.5.79.1 Possible axis synchronisations
Operating mode
Code Value Function
C1120
0 FB without function.
Assigns the data at the inputs directly to the outputs.
1 CAN Sync active
Synchronises the controllers to the sync telegram of the system bus.
2 Terminal Sync active
Synchronises the controllers to the sync signal of terminal X5/E5.
Synchronisation time
After mains connection and initialisation time of the controller, the FB SYNC1 also requires a
synchronisation time.
The synchronisation time depends on
•
the baud rate of the system bus (CAN-SYNC),
•
the starting time (input of the first SYNC telegram / signal),
•
the time between the SYNC telegrams,
•
the SYNC correction factor (C0363),
•
the operating mode of the FB SYNC1.