Technical data
3-1
L
EDSVS9332P-B EN 3.0
Part B
3 Technical data
3.1 Features
•
Single axis in narrow design
– thus space-saving installation
•
Power range: 370 W to 75 kW
– uniform control module and thus uniform connection for the control cables over the
complete power range
•
Heatsink can be separated
– the cooling can be achieved outside the control cabinet
(Push-through or ”Cold Plate” technique).
•
Power connections from the top (supply) or from the bottom (motor)
– simple connection for multi-axis applications
•
Direct connection of resolver or encoder feedback
– simple connection via prefabricated system cables (accessories)
– connecting cables can be plugged
•
Point-to-point positioning
– with or without velocity changeover
•
Touch probe positioning
•
Absolute or relative positioning
•
S-ramps.
•
Homingaccordingtodifferentmodes
•
Manual homing.
•
Manual positioning.
•
Manual positioning with intermediate stop
•
Simple programming via PC
•
Application configuration for control functions and input/output signals
– comprehensive function block library
– high flexibility in the adaptation of the internal control structure to the application
•
Integrated automation interface
– simple extensions of the controller functions
•
System bus for the connection of servo inverters and for the extension of input and output
terminals
•
Approval of standard devices UL 508, File No. 132659 (listed).
•
Approval 9371 BB (BAE) UL 508, File No. 132659 (listed).