Function library
7-182
L
EDSVS9332P-D21 EN 3.0
7.5.45.4 RESET
DFRFG-RESET = HIGH:
Resets setpoint phases which are internally added.
Activates the profile generator.
HIGH-LOW edge at DFRFG-RESET: Detecting the setpoint phase.
7.5.45.5 Detect phase difference
Monitoring the phase difference between input DFRFG-IN and output DFRFG-OUT.
Set limit value of monitoring via C0754.
Activates the monitoring: DFRFG-FAIL = HIGH
Storing the signal until DFRFG-RESET = HIGH.
The profile generator can accept a phase difference of up to ±2140000000 inc
(= 32000 revolutions).