Function library
7-181
L
EDSVS9332P-D21 EN 3.0
7.5.45.2 Quick stop
Removes the drive from the network and brakes it to standstill.
•
Activate with DFRFG-QSP = HIGH.
•
Set deceleration time via C0753.
•
Store the setpoint phase detected at DFRFG-IN.
•
Approach the setpoint phase via the profile generator after resetting the quick stop request.
t
DFRFG-IN
C075
C0751 C0751
DFRFG-QSP
t
DFRFG-OUT
C0753
Fig. 7-138 Quick stop DFRFG
7.5.45.3 Ramp function generator stop
Maintains the state of the profile generator during operation.
•
Activate with DFRFG-STOP = HIGH
•
Output of the last state at DFRFG-OUT.
•
Store the setpoint phase detected at DFRFG-IN.
•
Approach the setpoint phase via the profile generator after resetting the stop request.
t
DFRFG-IN
C075
DFRFG-STOP
t
DFRFG-OUT
Fig. 7-139 Ramp function generator stop