Lenze 9300 - Phase-Analog Converter (CONVPHA)

Lenze 9300
591 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function library
7-162
L
EDSVS9332P-D21 EN 3.0
7.5.38 Phase-analog converter (CONVPHA)
Three function blocks (CONVPHA1 ... CONVPHA3) are available.
Purpose
Conversion of a phase signal into an analog value.
CONVPHA1
CONVPHA1
CONVPHA1-OUT
C1002
± 199,99%
CONVPHA1-IN
C1001
2
C1000
1
Fig. 7-117 Function block CONVPHA1
Signal
Source Note
Name Type DIS DIS format CFG List
CONVPHA1-IN ph C1002 dec [inc] C1001 3 -
CONVPHA1-OUT a - - - - Limited to ±199.99 %
Function
Conversion with adaptation using divisor.
The conversion is performed according to the formula:
CONVPHA1OUT = CONVPHA1IN
1
2
C1000
100%
16384
CONVPHA2
CONVPHA2
CONVPHA2-OUT
C1612
± 199,99%
CONVPHA2-IN
C1611
2
C1610
1
Fig. 7-118 Function block CONVPHA2
Signal
Source Note
Name Type DIS DIS format CFG List
CONVPHA2-IN ph C1612 dec [inc] C1611 3 -
CONVPHA2-OUT a - - - - Limited to ±199.99 %
Function
Conversion with adaptation using divisor.
The conversion is performed according to the formula:
CONVPHA2OUT = CONVPHA2IN
1
2
C1610
100%
16384