Function library
7-74
L
EDSVS9332P-D21 EN 3.0
Status Started-break
Program processing is started but is interrupted by controller inhibit, QSP, TRIP, mains failure,
Fail-QSP or manual control (interruption). In order to continue the program processing a new
start edge is required.
Status output POS-STARTED = HIGH and
POS-RUNNING = LOW (for firmware version
2.5)
positioning status (C1283) = Started break.
Tip!
Firmware version
2.5:
The states Started and Started-break can be distinguished by the new status output
POS-RUNNING.
Firmware version < 2.5:
When the stand-by operation is activated Started-break cannot be identified!
The states Started and Started-break can only be distinguished via the positioning status
(C1283).
Status Stopped
Program and drive stopped, or drive will be stopped.
Status output POS-STOPPED = HIGH,
Positioning status (C1283) = Stopped,
or Stopped-rem, if C1280.B1 = 1 (GDC control),
or Stopped-dig, if input POS-PRG-STOP = HIGH,
Status Prg reset
Program processing is aborted and the drive is stopped. Actual PS No. (POS-ACT-PS-NO) is
set to program end.
Output POS-RESETED = HIGH,
output POS-ENDED = HIGH,
positioning status (C1283) = Prg-Reset-rem, if C1280.B2 = 1 (GDC control),
or Prg-Reset-dig, if input POS-PRG-RESET = HIGH,
current PS No. (POS-ACT-PS-NO) = 0 (program end)