Function library
7-154
L
EDSVS9332P-D21 EN 3.0
CONV5
CONV5
CONV5-OUT
CONV5-IN
C0658
C0657
C0655
C0656
Fig. 7-111 Function block CONV5
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
CONV5-IN a C0658 dec [%] C0657 1 1000
CONV5-OUT phd - - - - - Limited to ±29999 rpm
This function block is used to convert analog signals into speed signals.
The conversion is done according to the formula:
CONV5-OUT = CONV5-IN ⋅
15000 rpm
100 %
⋅
C0655
C0656