Function library
7-259
L
EDSVS9332P-D21 EN 3.0
SELPH2
SELPH2-IN1
SELPH2
C1667/1
C1669/1
SELPH2-OUT
SELPH2-SELECT
C1666
C1668
SELPH2-IN2
C1667/2
C1669/2
SELPH2-IN3
C1667/3
C1669/3
SELPH2-IN4
C1667/4
C1669/4
SELPH2-IN5
C1667/5
C1669/5
SELPH2-IN6
C1667/6
C1669/6
SELPH2-IN7
C1667/7
C1669/7
SELPH2-IN8
C1667/8
C1669/8
FIXED0INC
1
2
3
4
5
6
7
8
0
8
C1665
0
Fig. 7-210 Function block SELPH2
Signal
Source Note
Name Type DIS DIS format CFG List
SELPH2-SELECT a C1668 dec C1666 1 -
SELPH2-IN1 ph C1669/1 dec [inc] C1667/1 3 -
SELPH2-IN2 ph C1669/2 dec [inc] C1667/2 3 -
SELPH2-IN3 ph C1669/3 dec [inc] C1667/3 3 -
SELPH2-IN4 ph C1669/4 dec [inc] C1667/4 3 -
SELPH2-IN5 ph C1669/5 dec [inc] C1667/5 3 -
SELPH2-IN6 ph C1669/6 dec [inc] C1667/6 3 -
SELPH2-IN7 ph C1669/7 dec [inc] C1667/7 3 -
SELPH2-IN8 ph C1669/8 dec [inc] C1667/8 3 -
SELPH2-OUT ph - - - - -
- - C1665 dec - - displays the current selection
Function
•
An analog signal at SELPHx-SELECT directly selects an input and switches it to SELPHx-OUT.
– If SELPHx-SELECT = 0, SELPHx-OUT switches to FIXED 0 INC.
– If SELPHx-SELECT < 0, SELPHx-OUT switches to FIXED 0 INC.
– If SELPHx-SELECT > 8, SELPHx-OUT switches to SELPHx-IN8.
Tip!
You can select an input via a digital signal by connecting the FB CONVDAx before SELPHx-SELECT.