Function library
7-290
L
EDSVS9332P-D21 EN 3.0
Function
A total of 34 table positions is available.
•
Enter fixed setpoints under C1302.
– 30 table positions (VTVEL-No1 ... VTVEL-No30) are available.
– Subcodes (C1302/1 ... C1302/30) define the table position number.
•
Enter variable setpoints under VTVEL-INx.
– Four table positions (VTVEL-No31 ... VTVEL-No34) are available.
– Signal input via function blocks.
– The setpoints must be transmitted to the table positions before the program set starts and
has access to it.
•
C1382 indicates the setpoints (in % of vmax) on the table positions.
– Select table position (C1382/1 ... C1382/34) with subcode.
•
C1383 displays the setpoints (in inc) on the table positions.
– Select table position (C1383/1 ... C1383/34) with subcode.
•
The conversion from v [units/s] to v [inc] is performed according to the formula:
v[inc]= v [units∕s] ⋅
65536 [inc∕r] ⋅ gear nominator ⋅ 16384
Feed const. [units∕r] ⋅ gear denominator ⋅ 1000 [1∕s]
Tip!
Entries into the processing table are only required if FB inputs and outputs are used.