Function library
7-290
L
EDSVS9332P-D21 EN 3.0
Function
A total of 34 table positions is available.
Enter fixed setpoints under C1302.
30 table positions (VTVEL-No1 ... VTVEL-No30) are available.
Subcodes (C1302/1 ... C1302/30) define the table position number.
Enter variable setpoints under VTVEL-INx.
Four table positions (VTVEL-No31 ... VTVEL-No34) are available.
Signal input via function blocks.
The setpoints must be transmitted to the table positions before the program set starts and
has access to it.
C1382 indicates the setpoints (in % of vmax) on the table positions.
Select table position (C1382/1 ... C1382/34) with subcode.
C1383 displays the setpoints (in inc) on the table positions.
Select table position (C1383/1 ... C1383/34) with subcode.
The conversion from v [units/s] to v [inc] is performed according to the formula:
v[inc]= v [unitss]
65536 [incr] gear nominator 16384
Feed const. [unitsr] gear denominator 1000 [1s]
Tip!
Entries into the processing table are only required if FB inputs and outputs are used.