Configuration
7-366
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C1320
0
1
inactive
PFO 01
First switching PFO (no. of the PFO)
•
Program function output 1: Set an output
1 PFO1-NO 0
2
3
...
PFO 02
PFO 03
...
be
ore posi
ioning
2 PFO1-NO 0
...
31
32
...
PFO 31
PFO 32
... ... ...
100
101
102
ll PFO’s
PFO 01 ... 08
PFO 09 ... 16
32 PFO1-NO 0
103
104
...
PFO 17 ... 24
PFO 25 ... 32
C1321
0 0 level First switching PFO level
1 PFO1-LEVEL 0
1 1 level
2 PFO1-LEVEL 0
... ... ...
32 PFO1-LEVEL 0
C1322
0
1
inactive
PFO 01
Second switch ing PFO (no. of th e PFO)
•
Program function output 2: Set an output
1 PFO2-NO 0
2
3
...
PFO 02
PFO 03
...
a
er posi
ioning
2 PFO2-NO 0
...
31
32
...
PFO 31
PFO 32
... ... ...
100
101
102
ll PFO’s
PFO 01 ... 08
PFO 09 ... 16
32 PFO2-NO 0
103
104
...
PFO 17 ... 24
PFO 25 ... 32
C1323
0 0 level Second switching PFO level
1 PFO2-LEVEL 0
1 1 level
2 PFO2-LEVEL 0
... ... ...
32 PFO2-LEVEL 0
C1324 → Selection list 18
Waiting time (no. in VTTIME)
1 WAITTIME-NO 0 inactive
2 WAITTIME-NO 0 inactive
... ... ... ...
32 WAITTIME-NO 0 inactive
C1325
0 inactive JMP1: PFI no.
1 JMP1-PFI-NO 0
1
PFI 01
•
Number of a PFI for branch 1
2 JMP1-PFI-NO 0
2 PFI 02
... ... ...
...
...
32 JMP1-PFI-NO 0
C1326
0 0 level JMP1: PFI level
1 JMP1-LEVEL 0
1 1 level
•
Level of a PFI for branch 1
2 JMP1-LEVEL 0
... ... ...
32 JMP1-LEVEL 0
C1327 → Selection list 19
JMP1: PS no.
1 JMP1-PS 0 Prg. end
•
Branch 1 on program set No. (PS). Entr y of
2 JMP1-PS 0 Prg. end
he program se
No.
... ... ... ...
32 JMP1-PS 0 Prg. end