Troubleshooting and fault elimination
Troubleshooting
8-2
L
EDSVS9332P-E EN 3.0
Display via the LECOM status word C0150
Bit Meaning
0 FREE 0 freely linkable
1 IMP (pulse inhibit)
0 = enables pulses for power stage
1 = inhibits pulses for power stage
2 FREE 2 freely linkable
3 FREE 3 freely linkable
4 FREE 4 freely linkable
5 FREE 5 freely linkable
j6 f
d
=0(act.speed=0) 0=[n ≠ 0]
1=[n=0]
7 Ctrl. inhibit (controller inhibit) 0 = no controller inhibit
1 = controller inhibit
hex bin
0 0000 Device initialisation
2 0010 Switch-on inhibit
3 0011 Operation inhibited (controller inhibit)
8-11 Controller status
6 0110 Operation enabled
7 0111 Message active
8 1000 Fault active
9 1001 Power off
A 1010 Fail-QSP
12 Warning 0=nowarning
1=warning
13 Message 0 = no message
1 = message
14 FREE 14 freely linkable
15 FREE 15 freely linkable