Installation
4-27
L
EDSVS9332P-B EN 3.0
Terminal assignment
Signal type Function
Bold print = Lenze setting (C0005 = 20000)
Level Technical data
X5/28
Digital inputs
Controller inhibit (CINH) HIGH = start
LOW: 0 … +3 V
X5/E1
Freely assignable
Limit switch – traversing in negative direction
LOW
HIGH: +12 … +30 V
X5/E2 Freely assi gnable
Limit switch – traversing in positive direction
LOW
Input current at +24 V:
8 mA per input
X5/E3 Freely assi gnable
Start positioning program (condition: X5/E5 = LOW)
LOW-HIGH edge
Reading and writing of the inputs:
X5/E4 Freely assi gnable
Reference switch and touch probe input
HIGH
X5/E5
Freely assignable
Program active LOW
Reset error message TRIP LOW-HIGH edge
Reset positioning operation HIGH
Activate manual operation HIGH
X5/A1
Digital outputs
Freely assignable
Reference known
HIGH
LOW: 0 … +3 V
HIGH: +12 … +30 V
X5/A2 Freely assignable
Target position reached
HIGH
Load capacity:
Max. 50 mA per output
X5/A3 Freely assignable
Ready for operation
HIGH
(external resistance at least 480 Ω
at +24 V)
X5/A4 Freely assignable
PFO1
HIGH
Updating of the outputs:
Once per ms
X5/39 – GND2, reference potential for digital signals – Electrically isolated to GND1
X5/59 – DC supply for backup operatio n of the controller in the event of
mains failure
+24 V external Current demand: At least 1 A